Fire-retardant curtain fabric: class 1 UNE-EN 13773
Fire-retardant curtain fabric: in public assembly areas, the CTE requires class 1 of UNE-EN 13773. What it measures, its 5 classes, and what report to request.
Updated on November 20, 2026. Guide to choosing fabric. ISITEX does not certify that a project complies with regulations: what each project requires is decided by its designer.
In summary: a fire-retardant fabric for curtains in a public assembly venue (cinemas, theaters, bars, restaurants…) must have class 1 of the UNE-EN 13773. Always request the fabric's classification report. Do you need it in class 1? Write to us before purchasing: in the cart, the fabric is sold untreated, and we will tell you if it can be supplied with the fire-retardant treatment stated in the fabric's report.
What fire class does a fire-retardant curtain fabric need?
In buildings and public assembly establishments, the Technical Building Code requires suspended textile elements, such as stage curtains, drapes, and curtains, to be class 1 according to the UNE-EN 13773 standard. It is the best of the five classes in that standard. The curtain that closes a theater stage (the "stage house") is a different matter: if it is used to close it, the Technical Building Code requires it to withstand fire for 60 minutes (EI 60) and to be made of non-combustible material.
The Technical Building Code defines public assembly as buildings or establishments for cultural use (catering, entertainment, gatherings, leisure, sports, auditoriums, gaming, and similar), religious use, and passenger transport. For example: cinemas, theaters, auditoriums, assembly halls, nightclubs, bars, restaurants, gyms, churches, or stations.
For walls and ceilings, this standard does not apply: there, the Euroclass of the UNE-EN 13501-1 is required, which we explain in what the CTE requires of a fire-retardant fabric. And for armchairs and fixed upholstered seats in projects for cinemas, theaters, auditoriums, and assembly halls, the UNE-EN 1021-1 and 2, which we explain in UNE-EN 1021 and Crib 5. Each use has its own test, and one does not replace the other.
What UNE-EN 13773 measures
The UNE-EN 13773 standard classifies vertically hung fabrics: curtains, drapes, and similar uses, such as roller blinds and hangings. It does not have its own test: it brings together the results of three tests that measure two things.
- Does it ignite with a small flame? This is the UNE-EN 1101 test: a small flame is brought close to the edge of the fabric, first for 1 second and then for increasingly longer times, up to 20 seconds.
- Does the flame propagate? If the fabric did not ignite, propagation is tested with a larger flame (UNE-EN 13772). If it ignited, it is tested with the same small flame (UNE-EN 1102). To measure this, marker threads are placed at different heights to see which thread the flame reaches and burns, and whether flaming debris falls.
From this, the five classes emerge:
- Class 1: does not ignite with the small flame and, with the large one, does not burn even the first marker thread. No flaming debris falls.
- Class 2: does not ignite with the small flame and, with the large one, may burn the first thread, but not the third. No flaming debris falls.
- Class 3: does not ignite with the small flame, but with the large one burns the third thread or flaming debris falls.
- Class 4: ignites with the small flame, but does not burn through the third thread. No flaming debris falls.
- Class 5: ignites with the small flame and burns through the third thread, or flaming debris falls.
Six samples are tested. If at least two give a result of a worse class, the fabric remains in that worse class. If only one gives a worse result, three more samples are tested: if any of them give a worse result, it also remains in the worse class. And a fabric that has not been tested has no class.
The class applies to the fabric as tested
The report states what was tested. Before choosing, check two things in it:
- If the fabric had a fire-retardant treatment. The Camira class 1 reports that we have in "Downloads" are for fabric with treatment: the report states "FR TREATMENT". That class is valid for the fabric with that treatment, not for the same fabric untreated. If the fabric is treated by another company, the report for that treatment is required.
- If it was tested before or after washing. Those reports state that the sample was tested without prior washing, so they do not say what happens after washing it. If the curtain is going to be washed, ask the manufacturer or the person applying the treatment how it should be cleaned so that it does not lose its class.
A permanently fire-retardant fabric has the protection in the fiber itself, such as Trevira CS fabric (Trevira CS is a trademark of Trevira GmbH). Also in that case, for a curtain in a public assembly venue, what you must have is its report according to the UNE-EN 13773.
And in other countries
In the data sheets you will see other curtain tests. These are different tests, with other criteria:
- BS 5867-2 Type B, from the United Kingdom. The standard has three levels: A, B, and C, with C being the most demanding. According to Camira, Type B is often considered suitable for non-domestic use.
- NFPA 701, from the United States: a flame on the bottom edge of the hanging fabric, with a limit on flaming droplets and weight loss.
- French M1, from the NF P 92-507. It is not a Euroclass nor the old Spanish M1 classification.
In Spain, for a curtain in public areas, the Technical Building Code requires UNE-EN 13773. A report from another standard does not replace it on its own.
How to choose it in ISITEX
- In the cart, the fabric is sold without fire-retardant treatment. If your project requires class 1, write to us before purchasing and we will tell you if it can be supplied with the treatment from its report.
- Three examples with a class 1 report, treated: RIVET, PENTA and NESTA. The report is in "Downloads"; in the cart, they are sold untreated.
- In the curtain fabric by the meter guide are the fabrics that the manufacturer indicates for curtains. In the catalog and on each fabric's data sheet, those that only work with treatment are marked as curtains with treatment. A fabric appearing in the guide does not state its fire class: the class is in its report.
- In the catalog, the "class 1 EN 13773 with treatment" filter shows the fabrics that achieve it when treated, according to Camira's data. The report, when available, is in the "Downloads" section of each data sheet.
- The price of each fabric is on its data sheet: it is the professional price, per linear meter and excluding VAT. We sell only to professionals and companies with a tax ID (NIF).
- For fabrics that allow it, you can request a 1 m sample of the color you want, with a 15% discount on the price per meter. Each sample pays for its shipping separately.
How many meters of fabric does a curtain need
The maker decides, but the calculation is as follows:
- Fabric width: the width of the curtain multiplied by the fullness, that is, how many times more fabric than opening you want to create folds. With a fullness of 2, a 3 m wide curtain needs 6 m of fabric.
- Panels: divide that width by the fabric width and round up. With a 140 cm fabric: 6 ÷ 1.4 = 4.3, that is, 5 panels. With a 170 cm one: 6 ÷ 1.7 = 3.5, that is, 4 panels.
- Meters: multiply the panels by the length of each one. The length is the height of the curtain plus what the manufacturer requires for the hems and the header (the top part, where the tape or hooks go). With 2.6 m of height and 30 cm extra, each panel measures 2.9 m. With the 140 cm fabric: 5 × 2.9 = 14.5 m, and since it is sold by whole meters, 15 m. With the 170 cm one: 4 × 2.9 = 11.6 m, that is 12 m.
If the fabric has a pattern, add what is necessary to match it between panels. ISITEX curtain fabrics are sold starting from 5 m per color; if any requires more, its data sheet states so.
For other fire-related matters, there is the fire-retardant fabric by the meter guide. And if you get lost with the acronyms, the upholstery fabric glossary.
Frequently asked questions
Do hotels need fire-retardant curtains?
The Technical Building Code requires class 1 for curtains in buildings and establishments of public assembly, and a hotel is Public Residential use. In rooms, in principle, no. In the hotel's lounges, dining rooms, or performance areas, it depends on the project: the designer decides.
And in an office or a home?
In principle, the Technical Building Code does not require class 1 for curtains there: that section is only for public assembly. If the project or other regulations require more, whatever they require takes precedence.
Permanent fire-retardant fabric or with treatment?
Both can work if they have their class 1 report according to UNE-EN 13773. The permanent one has protection in the fiber; the treated one in a finish. In both cases, check what it was tested with and ask how to clean it without losing the class.
Is a Euroclass B-s1,d0 suitable for a curtain?
Not on its own. In the Technical Building Code, the Euroclass of UNE-EN 13501-1 is required for wall, ceiling, and floor coverings, not for hanging curtains. For a curtain, the Technical Building Code requires UNE-EN 13773.
Is M1 the same as class 1 of EN 13773?
No. M1 (Spanish or French) comes from other tests. For a curtain in public assembly in Spain, you must have class 1 of UNE-EN 13773.
Does BS 5867-2 work?
Not on its own. It is a United Kingdom test with different criteria. In Spain, UNE-EN 13773 is required.
What document is usually requested?
The classification report according to UNE-EN 13773 for the specific fabric, valid, with the treatment if it has one, and stating class 1. Confirm this with the designer.
A warning
This is a guide for choosing fabric. The classifications mentioned are those from each fabric manufacturer's reports. ISITEX does not certify that a project complies with regulations, nor that a fabric treated by others has the classification from the manufacturer's report: what each project requires is decided by its designer or the signing technician, and the current version of the Technical Building Code always takes precedence. Before buying, check the current report on the data sheet.
Sources
Consulted on November 20, 2026.
- Technical Building Code, Basic Document SI: section SI 1, subsection 4, point 4 (pages 17 and 18); section SI 3, table 2.1 (pages 22 to 24); annex SI A, definition of stage tower (page 43); annex G (page 86). Consolidated text following Royal Decree 164/2025.
- Technical Building Code, Basic Document SUA: annex A, definition of Public Assembly use.
- UNE-EN 13773:2003 in the AENOR store: AENOR lists it as current (confirmed in 2022).
- EN 13773:2003 in the iTeh Standards catalog, with its public excerpt: sections 3, 4, and 5 (table 1).
- Camira, "Global flammability standards": manufacturer's summary on BS 5867-2 and NFPA 701.
- Camira UNE-EN 13773 classification reports, under "Downloads" on each fabric's data sheet.