«schwer entflammbar» B1 fabric by the meter for curtains and upholstery: what DIN 4102-1 is, how it compares to Euroclasses, and what the MVStättV requires.

Updated on November 21, 2026. Guide to choosing «schwer entflammbar» fabric by the meter for curtains and upholstery in a project in Germany. ISITEX does not certify that a project complies with regulations: what each project requires is decided by its designer or the authority that approves it. The test reports we cite are from the manufacturer of each fabric, conducted by independent laboratories.

In summary: in Germany, a «schwer entflammbar» (flame-retardant) fabric is one that has class B1 of DIN 4102-1. In some cases, a European Euroclass is also valid, as we explain below. To choose it, request its B1 test report and check three things: whether the fabric was tested with a fire-retardant treatment, which colors are covered, and the validity date of the report. At ISITEX, the reports are in the "Downloads" section of each product sheet. Questions? Write to us or request a 1 m sample.

What does «schwer entflammbar» mean?

«Schwer entflammbar» means flame-retardant. In official German texts, it is written as one word, «schwerentflammbar». It does not mean that it does not burn. According to the Muster-Verwaltungsvorschrift Technische Baubestimmungen (MVV TB), published by the German Institute for Construction Technology (DIBt), such a material contributes little to fire and the flame spreads little, both while the flame is applied and after it is removed. And it must comply with this in a durable manner («dauerhaft»).

The MVV TB, in its Annex 4, Table 1.1, links each German requirement with a DIN 4102-1 class:

  • nichtbrennbar (non-combustible): class A2 at minimum.
  • schwerentflammbar (flame-retardant): class B1.
  • normalentflammbar (normally flammable): class B2.

Below that is «leichtentflammbar» (easily flammable).

How is class B1 tested?

Class B1 is tested in the so-called «Brandschacht», a vertical chamber with a burner at the bottom, according to DIN 4102-15 and DIN 4102-16. In each test, four strips of fabric form a vertical chimney over the flame. The B1 reports we have in "Downloads" measure:

  • What remains unburned: the average must be at least 15 cm, and no single strip can be completely burned.
  • The temperature of the smoke gases: the average cannot exceed 200 °C.
  • Smoke: the MVV TB also requires limited smoke for «schwerentflammbar», measured according to DIN 4102-15. The reports provide this value.

The reports also include the small flame test for class B2. And some note drops or pieces that fall while burning («burning droplets»). The MVV TB separates B1 alone from B1 that also does not drip while burning («nicht brennend abtropfend»). If your project requires that, look at that line in the report.

What is the relationship between B1 and Euroclasses?

European construction products are classified with the Euroclasses of EN 13501-1: letters from A1 to F, "s" for smoke, and "d" for burning droplets. The MVV TB, Annex 4, Table 1.2, states which Euroclass is sufficient as a minimum for each German requirement:

  • schwerentflammbar: C-s2,d2.
  • schwerentflammbar and no burning droplets: C-s2,d0.
  • schwerentflammbar and low smoke: C-s1,d2.
  • schwerentflammbar, no burning droplets, and low smoke: C-s1,d0.
  • nichtbrennbar: A2-s1,d0.

A better class is also valid: B-s1,d0 is above all those for «schwerentflammbar».

That table is for construction products with a harmonized European standard. A curtain or chair fabric is usually not a construction product. Whether the Euroclass is valid for your project or if the B1 report is needed is decided by the designer. Also look at how it was tested: in the data sheets, you will see the Euroclass "adhered" (fabric glued to a support) and "un-adhered" (not glued). A curtain hangs loose and a fabric on a panel is glued: each report is valid for its specific installation.

What does the MVStättV require for curtains, seats, and walls?

The Muster-Versammlungsstättenverordnung (MVStättV) is the model regulation for places of public assembly («Versammlungsstätten») prepared by the German Conference of Construction Ministers. Each federal state (Land) incorporates it into its own regulation, sometimes with changes, and the one for the Land where the project is located applies. This is what the current model version (from June 2005, with changes up to July 2014) says, in the sections we have consulted:

  • To which premises it applies: among others, those with rooms for more than 200 people, or several rooms that together exceed 200 people and share evacuation exits (§ 1). Also bars and restaurants, if they reach that size (§ 1 and § 2). It does not apply to churches, school classrooms, or museum halls (§ 1).
  • Stage curtains: «Vorhänge von Bühnen und Szenenflächen», stage and performance area curtains, must be at least «schwerentflammbar» (§ 33, paragraph 1). A performance area of less than 20 m² does not count as such (§ 2).
  • Scenery: «Ausstattungen», stage scenery pieces such as stage walls, must also be at least «schwerentflammbar». If the stage has an automatic extinguishing system, «normalentflammbar» is sufficient (§ 33, paragraph 3).
  • Seats: in venues with more than 5000 seats, the seats must be at least «schwerentflammbar» and their structure must be non-combustible (§ 33, paragraph 2).
  • Decoration: «Ausschmückungen», temporary decorations such as drapes, garlands, or flags (§ 2), must be at least «schwerentflammbar», and non-combustible in evacuation corridors and stairwells (§ 33, paragraph 5). They must be fixed to walls, ceilings, or scenery; if they hang loose in the room, they must be at least 2,50 m from the floor (§ 33, paragraph 6). And flammable items must be kept away from spotlights and heaters (§ 33, paragraph 8).
  • Wall coverings in rooms: at least «schwerentflammbar» and without flaming droplets (§ 5, sections 2 and 5). If a fabric covers a wall panel, the entire panel is the covering: it is not enough to look at the fabric alone.
  • Ceilings: ceiling coverings must be non-combustible; only in rooms up to 1000 m² is «schwerentflammbar» sufficient (§ 5, section 3). In foyers through which evacuation routes pass, and in staircases and evacuation corridors, ceilings and walls must be non-combustible: a fabric is not sufficient there (§ 5, section 4). And the structure supporting those coverings must be non-combustible, except in rooms up to 100 m² (§ 5, section 6).

In the sections we have consulted, the model version does not have a specific clause for curtains in room windows or for seating in smaller premises. If your project or your Land's regulations require B1, send what they request. There is a draft of changes to the model version, dated February 2025, which was not approved at the time of consultation.

What the reports themselves warn about

The B1 reports in «Downloads» state things that should be read before purchasing:

  • They are valid for the tested material, and some only for the tested colors.
  • Combined with other materials (a coating, a foam, a panel), the reaction to fire may worsen. DIN 4102-1 requires testing the assembly separately.
  • Some warn that they do not replace the «Verwendbarkeitsnachweis», the proof that a construction product can be used in Germany: the report is used to obtain it. For a construction material that must be «schwerentflammbar», such as a covered wall panel, the MVV TB requires an official test certificate («allgemeines bauaufsichtliches Prüfzeugnis»). Which document your project requires is determined by your project designer.
  • They have an expiration date: the reports include the date until which they are valid. Check that it is still current.

What about EN 13773 for curtains?

Some product sheets also include an EN 13773 report, the European standard that classifies curtains and which is required, for example, in Spain for public assembly venues. The MVStättV does not cite it: in Germany, the requirement is «schwerentflammbar». We explain this in fire-retardant fabric for curtains and EN 13773.

B1 fabric by the meter for curtains and upholstery at ISITEX

  • Upholstery fabric (for sofas and chairs) with a current B1 report for the untreated fabric, for example: UPLAND, TRACK and X2. Their reports note flaming droplets falling from time to time: they are not suitable where «without flaming droplets» is also required.
  • Fabric for curtains with a current B1 report for the untreated fabric, for example: UPLAND.
  • Only with fire-retardant treatment: RIVET, QUEST and OCEANIC have a B1 report for the treated fabric («+ FR Treatment»). In the shopping cart, they are sold untreated. If you need it treated, write to us before purchasing and we will tell you if the manufacturer can supply it with the tested treatment. The B1 of those reports is valid only with that treatment.
  • In the catalog, the «DIN 4102 B1» filter shows fabrics with B1 without treatment according to the manufacturer's data, and the «DIN 4102 B1 with treatment» filter shows those that achieve it when treated. Not all of them may be there: what counts is the report in «Downloads» for each product sheet, and its date.
  • More guides: fire-retardant fabric by the meter, curtain fabric by the meter and upholstery fabric by the meter. The fact that a fabric appears in a guide does not state its fire class: the class is in its report.
  • The price of each fabric is on its product sheet: it is the professional price, per linear meter and excluding VAT. The minimum order is 5 m per color, unless the product sheet states otherwise. We sell only to professionals and companies with a tax ID or VAT number.
  • For fabrics that allow it, you can request a 1 m sample of the color you want, with a 15% discount on the price per meter. Each sample pays for its shipping separately.
  • We ship throughout Europe. Outside the European Union, for example to Switzerland, customs and duties are separate.

What about Austria and Switzerland?

This guide explains the German rule. Austria has its own building guidelines, those of the Austrian Institute of Construction Engineering (OIB), and Switzerland has its fire protection standards, those of the Association of Cantonal Fire Insurance Companies (VKF). In some product sheets, you will also see Austrian tests (ÖNORM B 3825 and ÖNORM A 3800-1). What each project requires is determined by your project designer.

Frequently asked questions

Does a «schwer entflammbar» fabric burn?

Yes, but very little: it contributes little to the fire and the flame spreads very little. What does not burn is «nichtbrennbar».

What is the difference between B1 and B2?

B1 is «schwerentflammbar» (hardly inflammable) and B2 is «normalentflammbar» (normally inflammable). Where «schwerentflammbar» is required, B2 is not sufficient.

Is a Euroclass B-s1,d0 valid instead of B1?

For construction products with a harmonized European standard, the MVV TB considers it sufficient for «schwerentflammbar». For a curtain or upholstery, confirm this with the project designer.

Can B1 be obtained for a fabric that does not have it?

With a fire-retardant treatment, only if there is a B1 report for the fabric with that treatment. Write to us before purchasing.

Do cinema or theater seats need B1?

In the model version of the MVStättV, the requirement for «schwerentflammbar» seats applies to venues with more than 5000 seats. Your Land's regulations or the project may require more.

Is B1 lost when washing the fabric?

The MVV TB requires that the material complies with it in a durable manner. If the fabric has a fire-retardant treatment, ask the applicator how to clean it without losing the class.

What document is usually requested?

The B1 test report according to DIN 4102-1 for the specific fabric, valid and including the treatment if applicable, and the supporting documentation requested by the project. Confirm this with the project designer.

A warning

This is a guide for choosing fabric. The classes cited are those from the manufacturer's reports for each fabric. ISITEX does not certify that a project complies with regulations, nor that a fabric treated by others holds the class stated in the manufacturer's report: what each project requires is decided by its project designer or the approving authority, and the current regulations of the Land where the project is located always prevail. Before purchasing, check the valid report in the technical data sheet.

Sources

Consulted on November 21, 2026.